Home About Us Products Enquiry Contact Us
Products
SCIENTIFIC INSTRUMENTS

 

R.F. Oscillator TE-92 Conductivity Bridge TE-94 R.F. Oscillator TE-92
Oscilloscope : TE-96 A.F. Oscillator TE-95 (Bridge Experiments) A.F. Oscillator TE-93-B (Digital)
Pulse Generator : TE-123 T.V. Pattern Generator TE-121 (Black and White) L.C.R. Bridge TE-98
Dual Trace Oscilloscope : TE-96A V.T.V.M. : TE-63 Distortion Factor Meter : TE-202

 

A.F. Oscillator TE-95 (Bridge Experiments)
A fix frequency Oscillator for Bridge Experiments, workable on 220 Volts 50 Hz, Giving variable output 0 to 10 volts P-P at 1000 Hz. Accuracy ±2% Output impedance 600 Ohms.

A.F. Oscillator TE-93 (Function Generator)
Generates frequency from 1 Hz to 250 KHz in 5 steps wave form is sine square and Triangular.  Output is variable from 0 to 10 Volts Accuracy ± 3% or 2 Hz. Output Impedance 50 ohms.  Solid State. Workable on 220 v 50 Hz complete I.C. version with coarse and fine controls for output and frequency select.
Dimension 11"x5 1/2 x 5"

A.F. Oscillator TE-93-B (Digital)
same as above, with  digital read out. specification ; wave form  sin\sq \ triangular frequency Range:1Hz to 250 k Hz in five selectable bands. Amplitude: 1to10  V P-P for continuous variation  in three  coarse steps and  a fine control.

Output impedance-50 ohm
Read out- Digital
Dimension: 13"x6"x5"

A.F. Oscillator TE-91 (Function Generator) Cum Digital
Frequency Meter Variable from 1 Hz to 1 MHz in five decade ranges Accuracy ±2% or 1 Hz. Six steps output 1 mV to 20V open circuit, continuously variable. Frequency response ±0.3 db from 20 Hz to 20 KHz. Setting at KHz, 0-5 dB, 10 Hz to100 KHz. Output Impedance 600 Ohms. The instrument is solid state and workable on 220 Volts 50 Hz. Sine, Square waves, Read out Digital. Frequency meter can be used to read 10 Hz to 10 MHz and seperate terminals in provided for that.

Dimension : 13"x6"x5"

R.F. Oscillator TE-92
Variable 100 KHz to 30 MHz. The instrument is to deliver modulated output and  continuous wave form.  The frequency range is covered  in eight bands , modulation frequency is 400 Hz, and also available on output terminals. M Modulation depth 30% Accuracy  ±2%

R.F. Oscillator TE-92
General use of instruments is in ultra sound and letcher wire experiments.  Generate frequency 3 MHz with high output volts.  The frequency is calibrated on dial.

R.F. Oscillator (AM/FM)TE-92C
Union instrument for testing Radio and T.V. Set variable from 200 KHz to 280 MHz in seven band output modulated  at 400 Hz and 1 KHz with calibrated dial.  F.M. modulating automatically switched above 50 MHz, output variable 0 to 200 m.V

Crystal Marker Generator : T E-120
Instruments is standard frequency generator, workable 220V 50 Hz, crystal used is of fundamental frequency of 1 MHz, Frequency output level is T.T.L. compatible.  Four decade dividing circuit is used to make it variable 1 Hz to 1 MHz.  Digital indicator 4 digit.

T.V. Pattern Generator TE-121 (Black and White)
The Instrument generate seven type of pattern and sound of 1 KHz.  It is ideal for T.V. Testing and alignment of sync circuit and quick testing of R.F. I.F. Video and sound circuits.  The equipment work on all 12 channel of T.V. It is generates pin point frequency for the desired channel.  The design is as per C.C.I.R. standard.  Workable on 220 V 50 Hz (The Pattern generated are cross, horizontal, vertical, dot, side cross and blank).

T.V. Pattern Generator TE-121 (Black and White)
The instrument find application for checking coloured T.V. Line frame, time bass, linearity, picture, dimensions, video, I.F. sound and functional performance of Audio/Video Stages.  It give four coloured and three black and white patterns.  Specifications : Line frequency-15625 Hz Fixed

Pulse Generator : TE-123
The instrument produces rectangular pulses. The pulse rate and the pulse width is variable. The pulse amplitude can be selected to trigger T.T.L. Circuit. Specification :-

Pulse Time : 10 Micro sec. to 1 sec. variable
External Triggering : 2-20 Volts.
Pulse Width : 1 Micro sec. to 1 sec.
Output Voltage : 1 Volt to 15 Volts
Rise Time : 10 sec. in 50 ohms load.

Conductivity Bridge TE-94
This instrument is to measure Conductance of Electrolyte solution or its Resistance directly. Working frequencies are 50 Hz and 1 KHz. Direct calibration in MHO. Resistance 0.1 Ohms to 1 Meg ohms. Conductance 1 MHO to 1 Micro MHz in seven ranges, Accuracy ±1% mid scale and ±3% on both ends. Null detection on meter with Conductivity Cell.

L.C.R. Bridge TE-98
Fully Solid state instrument, workable on 220 V 50 Hz or on 9 Volts Battery, useful for the wide range measurement of Resistance, Capacitance and Inductance.
Resistance Range : 0.01 Ohms to 1 Meg Ohms in seven ranges. Capacitance 2 PF to 110 MFD. Inductance 2 micro Henries to 110 Henry in seven ranges Accuracy ±1%, D-0.001 to 10Q=1 to 10.

Dimension 14"x9"x5½"

Dual Trace Oscilloscope : TE-96A
It is a 20 MHz Dual Channel Oscilloscope that s ideal for, professionals as well as students undergoing technical studies. It is a rugged, light weight instrument that features a brijght, sharply defined trace on a 80 by 100 mm cathode ray tube. The internal trigger signal is ac coupled. An external triggering signal or an external Z-axis modulation signal can be applied via a front panel or rear panel connector and the source selector switch. The horizontal system provides calibration sweep speeds from 0.2s to 0.1 Micro S per division. For greater measurement accuracy a x5 magnifier circuit extends the maximum sweep speed to 20 ns per division. Special Features : Synchronisation of the signals from the two channels can be identified by a Red LED, marked as "READY", present on the right hand side top on the front panel.



Frequency Bandwidth DC - 20 MHz
Deflection Factor     5mV/div-10V x div x 5
Sweep Factor 0.2s-0.1s/div. ±5%
Trigger Synchronization  Int, Alt, Line, Ext. TV.
Vertical type CH1, CH2, Alt, Chop
Sweep Mode Auto, Trigger, Single time

Oscilloscope : TE-96
Fully Solid state workable on 220 volts 50 Hz. All supplies are stabilized for accurate and stable operation. Single beam with a band width DC to 10 MHz. The accurate triggering of time base enable clear and stable display on screen 8x8 cm. Vertical deflection can be selected for either A.C. or D.C. provision or attenuation in the input circuit, calibrated from 5 mV to 50V/cm.

Specifications :
Band width  Vertical D.C. to 10 MHz (3db)
Sensitivity 10mV/Cm Maximum
Input Impedance 1 M Ohm.
Square wave calibration 2 VP-P.
Triggering Internal from vertical amplifier or external.
Sweep Time Factor 0.1 us/Div. 0.1s/div. ±5%.
Horizontal Amplifier :
Band width DC to 1 MHz.
Display 8x8 cm square
Power requirement 25 Watt 230 V 50 Hz.
Dimension 8"x5½"x11"

Oscilloscope : TE-97
This instrument is for college laboratory workable on 220 Volts. A.C. Vertical bandwidth 10 HZ to 2 MHz. Cathode Ray tube dimensions 8 cm. Sensitivity vertical 30 mV/Cm. Time base frequency 16 Hz to 50 KHz with Lock and Fine  arrangement All controls for Focus, Intensity. X and Y shift are on rear panel. Built in arrangement for 50 Hz output for demonstration of lissageious figures.
Signal Tracer : TE-99
The instrument is used to locate faults in radio receiver. Workable on 220 Volt Hz. Probe 100 KHz to 30 MHz is provided to detect R.F. and I.F. Signal. The audible capability is upto 5 Watts. Complete with A.F./R.F. Probes and loudspeaker.
Power Output Meter : TE-100
The instrument is to measure power directly across on load. The calibration is on a analogue meter and variable load can be selected by an band switch. The variation of load is 4, 8, 16, 32, 250, 600, 5000 ohms, range is 0-10 watts in two steps. 0 to 1 and 1 to 10 watts F.S.D., workable on 220 Volts, 50 Hz.
V.T.V.M. : TE-63
Workable on 220 V 50 Hz compiled in steel cabinet, rectangular meter 110x90mm.
Suitable for measurement of A.C. / D.C., Resistance 0-1000M. Ohms in seven ranges R.F. 0.50 Volts R.M.S. in 4 ranges.
D.C. Range : 1.5, 5, 15, 150, 500, 1500 FS-D
A.C. Range : 1.5, 5, 15, 50, 150, 500, 1500 F.S.D.
Resistance : 1K, 10K, 100K, 1M, 10M, 100M, 1000M.
Absorption Wave Meter : TE-132
The instrument is to detect Radio frequency radiations. The wave length and strength can be known by tuning on L.C. Circuit. It consists of variable capacitor and two plugable inductors. Frequency covered is 1 MHz to 10 MHz.
Absorption Wave Meter : TE-132 B
Same as above with six coils 100 KHz to 100 MHz.
Transistor Testor : TE-133
Instrument is to test P.N.P. and N.P.N. transistors general purpose and low power. The indicator comprises an moving coil meter calibrated in gain or hfe. Socket provided for connecting transistor. Workable 220 V 50 Hz.
Distortion Factor Meter : TE-202
Instrument is measure unwanted distorted signal in an amplifier, by feeding pure sine wave and amplified signal passing through filters and distorted signal measured on meter in terms of percentage. The instrument consists of sine wave generator filter circuit and meter. Workable 220 V 50 H. The capability of this instrument is to measure distortion in audioable range 20 Hz to 20 KHz.
Q Meter : TE-203
The instrument is to measure ! (Quality factor) of an inductor. which is necessary to know when designing coils or transformer, measuring frequency is 1 KHZ or 10 KHZ. Measuring range is 0.1 to 100. Moving coil meter is used as indicator. Workable 220 V 50Hz. Balancing dial is directly calibrated in terms of Dimension : 14"x9"x5½"
Clamp ON Meter : TE-107F
Instrument is to measure alternating voltage and current without connecting the same, measurement is by induction effect in coil.
Measuring Range : 0 - 500 V A.C.
0 - 500 Amps. A.C.
D.C. and Resistance measure by leads.
Sound Level Meter
The instrument is to measure sound pressure in public palaces, workshop, machinery mills, vehicles. The sound is picked up and amplified attenuated and fed moving coil meter calibrated in decibles, measuring range: 50 to 110 db., Battery operated.
Stroboscope
Instrument is to see the stroboscopic effect and determine the speed of moving articals without connecting it with revolving wheel shaft. Measuring range : 100 RPM to 10,000 RPM. with calibrated dial, Mains operated. Optional battery
Products
Scientific Instruments
Digital Instruments
Application For Photo Cells and Solar Cells
E/M Apparatus
Microprocessors
Semi Conductor Devices
Laser Experiment
Verification of Various Laws & Conservation of Signal
Verification of Network Theorem
Demonstration Models
Amplifiers
Study of Multivibrators
Oscillators
Digital Electronic Experiments (Computer Principles)
Training Kits for Communication Lab
Active & Passive Filter Circuits
Power Supplies and Transformers
Switchboard Pannel, Ammeters, Voltmeters , Rectifiers
Portable Wheat Stone Bridge
Industrial Kelvin Double Bridge
Universal Moisture Meter
Triode Moisture Meter
Grains Moisture Meter
Digital Moisture Meter
Infrared Moisture Balance
Digital Seed Counter
Moisture Meter For Wood
Moisture Meter For Soil

    © 2007 Triode Electronics India    Home         Products          Enquiry          Contact